Catia cannot find license server

How to point users to the license server that I set up before in CATIA V6R2013X ???

Log In. Thank you for helping keep Eng-Tips Forums free from inappropriate posts. The Eng-Tips staff will check this out and take appropriate action. Click Here to join Eng-Tips and talk with other members! Already a Member? Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Register now while it's still free! Already a member? Close this window and log in. Are you an Engineering professional? Join Eng-Tips Forums! Join Us! By joining you are opting in to receive e-mail. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Related Projects. I installed 64bit Catia V5 R18 on a 64bit Win 7 enterprise. I set up the License Use Runtime as it was earlier for floating license. The Basic Lisence Tool can see the license server only when I turn off the windows firewall, but I cannot start Catia. The License manager says: "You have not requested a configuration or product license. Could somebody help why it's happen? Check the licenses you have access to.

Unable to talk to license server after Windows update


Log In. Thank you for helping keep Eng-Tips Forums free from inappropriate posts. The Eng-Tips staff will check this out and take appropriate action. Click Here to join Eng-Tips and talk with other members! Already a Member? Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Register now while it's still free! Already a member? Close this window and log in. Are you an Engineering professional? Join Eng-Tips Forums! Join Us! By joining you are opting in to receive e-mail. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Related Projects. I have set up the network license server and central registry server on a Windows Server machine with the default ports for network and for central registry. When I run the Basic License Tool on the client workstation which I have configured as a network client with direct binding it cannot see the license server on the network. I tried disabling the Windows Firewall on the server and the client was able to connect to the server.

Could not obtain a license for SolidWorks. Cannot connect to license server.


When I launch the program I do get an error: You have not requested a configuration or product license. Click okay and select one config license using the License manager dialog. The activation limit has nothing to do with the number of servers you can install. You have one license and you have the option to use that in a downgraded status. For example, if for some reason you can't use R2 you can opt to useR2 or instead, but you still only have one license. Now, if I understand correctly you can install that on hardware and then have one VM running inside it that also uses the same license but that's the legal limit. Then again, they change their definitions on a regular basis and even their licensing experts don't often agree on what the rules mean. Is this a New install? Has it worked before? How are the licenses distributed from the server? It was funny, I was googling about 20 minutes after I made this post and this post came up as one of the top 10 results. So hopefully someone wont have to dig as far as I did! To continue this discussion, please ask a new question. Get answers from your peers along with millions of IT pros who visit Spiceworks. I have: Turned off the firewall on the server and client to verify its not that checked the file that contains the server and port number to verify it is correct When I launch the program I do get an error: You have not requested a configuration or product license. Problem is all the keys are grayed out. Anyone have any thoughts on where I can go with this? CATIA 3. Best Answer. So I just figured it out. It ended up being a Windows Update that made it not work. We found 5 helpful replies in similar discussions:. Fast Answers! Ghost Chili. B-C Sep 29, Yes multiple activation for that key. Was this helpful?

How is the network license server specified for the CATIA V5 CAD program?


In order to run Abaqus, a license needs to be checked out from a license server. Installing the license server and reading in the license file is not very complex in general. Difficulties can arise though, especially when the license server is on a different computer than the computer you want to run Abaqus on. We will discuss FLEXnet licensing here. During a new installation of the Abaqus CAE software, the license server needs to be filled in, so Abaqus knows where to obtain a license. This implies the license server should already be installed and running. In fact, the installation will not continue normally without a reference to a working license server being filled in. For external license servers, either the computer name or ip-address can be used. A port number can be specified, if you wish to work with a non-default port. Otherwise, it is not necessary. By default, the first available port in the range is used. Usually the main reason for wanting to use a non-default port is that FLEXnet is used for different programs. Error to conect to license server during installation. In this case, trying the points discussed below may resolve the issue. In some cases it is necessary to let an existing Abaqus installation refer to a different license server. The computer that is running the license server is specified in the environment file. The location of the environment file changed between Abaqus 6. Up to and including Abaqus 6. Changing computername allows you to refer to a different license server. A port number can be included in front of the -sign. It may not be possible to save a modified. In this case copying the file to a different location, making the modification, saving it and pasting it back instead of the original file may allow you to make the modification. Any settings in these. If the license server was modified in the. Clicking Perform Status Enquiry in the Server Status tab, shows the current status of the license server. It should indicate that the license server is UP and list the amount of tokens that are available and in use. If this is not the case, the license server is not running properly. One option is, that the license server is not started. The configuration of the server can be seen in the Config Services tab. Check the path to the lmgrd. This debug log file should exist it can be empty though. Store any changes using Save Service. Keep in mind that the license file is MAC-address specific. If the license server is running properly, usually there are no issues if you want to run Abaqus on the same computer. If you want to run Abaqus on a different computer than the license server, additional challenges can arise. In some cases, there is no connection with the server computer at all. This can be checked by pinging it: typing. If you nicely receive replies, a connection can be made.

Enrolling Nodelock Licenses After the Installation

The role of the License Manager is to allow you to reserve licenses before using these products. You will not be able to work with any Version 5 products until you have first reserved the corresponding licenses. If you are using network licensing, selecting this tab contacts any license servers to update the list of available configurations and products. Licensing Information The "Licensing Information" section contains the following information: Target id : specifies the target id of your computer Display Type : informs you whether you are running on a local or remote display; Local : you are running on a local display and you can work with either nodelock or server licenses Remote : you are running on a remote display and you can work with server licenses only. Active servers : if you are using network licensing, the list of all active and the number of available license servers is now displayed like this:. The name of the server you are using is displayed in the field opposite. Click the the up and down arrows to display the list of servers available. If you are using nodelocked licensing only in other words, if you are not using network licensingthe following is displayed:. In principle, a license granted by a LUM license server to a V5 session is released when the V5 session stops. The license is also automatically released when a V5 session crashes. However, it may occur in the event of certain severe crashes or network problems, that the V5 session cannot instruct the license server to release the license, so the license is not released. To prevent the license from being retained endlessly by the license server, there is a specified period of time referred to as the "heartbeat" after which the license server considers the V5 session to be dead, and releases the license. This heartbeat is communicated to the license server by the V5 session when the license is first requested. Originally, the value of the heartbeat was set by default to approximately 17 mn, which meant that a license could be incorrectly retained by the license server up to 17 mn, and could not be customized. During this period of time, this license cannot be granted to another user. However, it can still be granted to the same user on the same machine on which the severe crash occurred. Now, you can set the heartbeat using the Frequency option. The default value is the same as before: approximately 17 mins. This is the maximum value represented by the value MAX in the list and cannot be increased. Decreasing the heartbeat value will decrease the maximum period of time during which a license can be inadvertently retained by the license server. You can set the appropriate value by increments of 1 min. Consequently, the heartbeat can be set to any of the following range of values: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 and MAX. Note: because the V5 session must contact the license server more frequently, decreasing the heartbeat leads to increased network load and to increased license server workload.

DS License Server(DSLS)의 Computer ID와 Catia의 Server ID가 다른 경우 해결방법



Comments on “Catia cannot find license server

Leave a Reply

Your email address will not be published. Required fields are marked *

You may use these HTML tags and attributes:

<a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <s> <strike> <strong>